Advantages
Exterior wall with Silka XL Basic and core insulation boards URSA GEO KDP 32/V incl. edging strips URSA XPS N-MRS and Silka facing bricks
- High durability and weather resistance
- Excellent thermal insulation with WLS 032
- Preventive fire protection through the use of a non-combustible insulating material.
- Economical construction due to large formats

Product details
URSA GEO core insulation board KDP 32/V
thermal insulation panel made of mineral wool with a water-repellent finish throughout, laminated on one side with yellow glass fleece, diffusion-open
Application brochure (PDF)
Product characteristics
URSA core insulation board 32/V / KDP 2/V
MW-EN-13162-T3-DS(70,-)-WL(P)-MU1-AFr5
Eigenschaften | Daten | Einheit | Norm |
---|---|---|---|
Nennwert der Wärmeleitfähigkeit (λD) KDP 32/Vs KDP 2/Vs |
0,031 0,034 |
W/(m·K) W/(m·K) |
DIN EN 13162 DIN EN 13162 |
Bemessungswert der Wärmeleitfähigkeit (λ) KDP 32/Vs KDP 2/Vs |
0,032 0,035 |
W/(m·K) W/(m·K) |
DIN 4108-4 DIN 4108-4 |
Wasseraufnahme | ≤ 3 WL(P) | kg/m³ | DIN EN 12087 |
Brandverhalten Euroklasse | A1 | DIN EN 13501-1 | |
Wasserdampfdiffusion μ | MU1 | DIN EN 12086 | |
Dickentoleranzklasse Ti | T3 | DIN EN 13162 | |
Strömungswiderstand AFr | ≥ 5 (AFr5) | kPa·s/m² | DIN EN 29053 |
URSA Glaswolledämmstoffe sind gesundheitlich unbedenklich, mit dem RAL-Gütezeichen „Erzeugnisse aus Mineralwolle“ gekennzeichnet und freigezeichnet
nach Gefahrstoffverordnung, Chemikalienverbotsverordnung und EU-Richtlinie 97/69 Anmerkung Q.
Product dimensions
λ * W/(m·K) | Dicke mm | Breite mm | Länge mm | Inhalt m²/Paket | Inhalt Pakete/Palette |
---|---|---|---|---|---|
032 | 60 | 625 | 1.250 | 6,25 | 20 |
032 | 80 | 625 | 1.250 | 4,69 | 20 |
032 | 100 | 625 | 1.250 | 3,91 | 20 |
032 | 120 | 625 | 1.250 | 3,13 | 20 |
032 | 140 | 625 | 1.250 | 2,34 | 20 |
032 | 160 | 625 | 1.250 | 2,34 | 12 |
032 | 180 | 625 | 1.250 | 2,34 | 12 |
032 | 200 | 625 | 1.250 | 1,56 | 12 |
λ * W/(m·K) | Dicke mm | Breite mm | Länge mm | Inhalt m²/Paket | Inhalt Pakete/Palette |
---|---|---|---|---|---|
035 | 40 | 625 | 1.250 | 9,37 | 28 |
035 | 50 | 625 | 1.250 | 7,81 | 28 |
035 | 60 | 625 | 1.250 | 6,25 | 28 |
035 | 80 | 625 | 1.250 | 4,69 | 28 |
035 | 100 | 625 | 1.250 | 3,91 | 28 |
035 | 120 | 625 | 1.250 | 3,12 | 28 |
035 | 140 | 625 | 1.250 | 2,34 | 28 |
035 | 160 | 625 | 1.250 | 2,34 | 20 |
* Bemessungswert der Wärmeleitfähigkeit
Product characteristics
Silka facing brick "Fläming white" embossed
Artikel | wall thickness mm |
Druck- festigkeits-/ Rohdichte- klasse |
Abmessung L x B x H (mm) |
Steingewicht ca. [kg/St.] |
Geregelt durch |
Steinbedarf |
Normal - mörtelbedarf ca. [l/m²] |
Arbeitszeitrichtwerte1) [h/m²] voll/gegliedert |
|||
---|---|---|---|---|---|---|---|---|---|---|---|
ca. [St./m²] |
ca. [St./m] |
||||||||||
Silka KS Vb DF glatt Silka KS Vb NF glatt |
115 | 20–1,8 | 240 x 115 x 52 240 x 115 x 71 |
2,6 3,5 |
DIN EN 771-2 DIN 20000-402 |
64,0 48,0 |
- - |
26,0 24,0 |
1,33/1,47 1,11/1,20 |
||
Silka KS Vb 2 DF glatt | 115 | 240 x 115 x 113 | 5,6 | 32,0 | - | 17,0 | 0,84/0,93 | ||||
Silka KS Vb 3 DF glatt | 175 | 240 x 175 x 113 | 8,5 | 32,0 | - | 26,0 | 0,84/0,93 | ||||
Silka KS Vb 5 DF glatt | 240 | 300 x 240 x 113 | 14,6 | 26,0 | - | 34,0 | 0,84/0,93 | ||||
Silka KS Vb NF bruchrau Läufer Silka KS Vb NF bruchrau Läufer/Kopf Silka KS Vb NF bruchrau Ecke 135 ° Silka KS Vb 2 DF bruchrau Läufer Silka KS Vb 2 DF bruchrau Läufer/Kopf |
95 | 240 x 95 x 71 210 x 95 x 71 215 x 95 x 71 240 x 95 x 113 200 x 95 x 113 |
2,9 2,5 2,6 4,6 3,9 |
48,0 – – 32,0 – |
– 12,0 12,0 – 8,0 |
20,0 – – 14,0 – |
1,11/1,20 1,11/1,20 1,11/1,20 0,84/0,93 0,84/0,93 |
||||
Silka KS Vb NF bossiert Läufer Silka KS Vb NF bossiert Läufer/Kopf Silka KS Vb NF bossiert Ecke 135 ° Silka KS Vb 2 DF bossiert Läufer Silka KS Vb 2 DF bossiert Läufer/Kopf |
240 x 95 x 71 225 x 95 x 71 215 x 95 x 71 240 x 95 x 113 215 x 95 x 113 |
2,9 2,7 2,6 4,6 4,2 |
48,0 – – 32,0 – |
– 12,0 12,0 – 8,0 |
20,0 – – 14,0 – |
1,11/1,20 1,11/1,20 1,11/1,20 0,84/0,93 0,84/0,93 |
1) Intern ermittelte Werte
Silka facing brick identification:
- Frost-resistant F2 (test of at least 50 freeze-thaw cycles)
- Selected raw material input from natural regional deposits
- At least one clean-edged head and runner side and a visually very bright and uniform appearance
- Excellent soundproofing and fire protection included
- Processing with Silka facing mortar ("light" or "grey").
The Silka facing mortar is precisely matched to the suction characteristics of the Silka facing brick and permits reliable processing.
Typical applications for manual brick lining:
- Optically very attractive exposed brickwork on and in buildings
- garden walls
- infills
Advantages:
- Manual brick lining and small formats ensure flexible application possibilities, especially outdoors.
- Small dimensional tolerances facilitate your own bricklaying work
- Very good sound insulation and fire protection
- Optimum summer thermal insulation
Related products
URSA XPS D N-III-L
URSA XPS D N-III-L TWINS
Wall edge strip URSA XPS N-MRS
- Nominal value of thermal conductivity 0.035 W/(mK)
- Rated value of thermal conductivity 0.036 W/(mK)
- Rated value of thermal conductivity 0.036 W/(mK)
- Dimensions: Length x width x thickness = 1,250 x 100 to 180 x 80 mm
Go back to Silka / Ursa
system solutions
system solutions